""" + ORG_LD + """
opheliamyers221@gmail.com +86 131 5623 3808 WhatsApp

Air Separation Projects Delivered Worldwide

Nearly 300 ASU sets, 2,000+ project cases, 20+ export countries - Russia, Turkey, Turkmenistan, Libya, Iran, Iraq, Algeria, Nigeria, Cameroon, Vietnam, Thailand, Brazil, Indonesia. A representative slice:

KDONAr-84000 - Large gaseous ASU, China

KDONAr-84000

Large gaseous ASU, China. 84,000 Nm³/h-class oxygen at 99.5% with argon extraction - part of the 3 plants we have delivered at the 50,000 class. Turbo-expander refrigeration, internal-compression product pumping, full argon distillation unit.

KDONAr-42000 / 40000 / 1200 - Cryogenic ASU group, steel site

KDONAr-42000 / 40000 / 1200

Cryogenic ASU group, steel site. A mixed-capacity train (42,000 and 40,000 oxygen plus a 1,200 argon unit) covering a steel complex' baseload and argon revenue stream on one plot plan.

KDONAr-8200 / 8900 / 280 - ASU + argon, chemical park

KDONAr-8200 / 8900 / 280

ASU + argon, chemical park. 8,200 and 8,900 Nm³/h oxygen service with a 280-class argon plant - the middle capacity band where our ultra-low-pressure flow earns its electricity promise.

KDONAr-3000Y / 4000Y - Full-liquid plants, gas company

KDONAr-3000Y / 4000Y

Full-liquid plants, gas company. Liquid oxygen/nitrogen/argon production for an independent gas distributor: Y-series low-pressure cycles, vacuum-insulated storage, tanker filling stations. The plant that turns a gas user into a gas business.

KDONAr-50 - Small ASU, medical/industrial

KDONAr-50

Small ASU, medical/industrial. The small end of the family - SKDO/KDON-class units for hospitals, fabricators and village-industrial gas shops: 50-250 Nm³/h oxygen at 99.5%, turbine-expander refrigeration, one-crew operation.

Furnace exhaust recovery, cold-rolling line - N2/H2 recovery, bell-type furnace park

Furnace exhaust recovery, cold-rolling line

N2/H2 recovery, bell-type furnace park. Closed-loop protection-gas recovery on a batch-annealing park: capture, cool, clean, recompress, re-inject - the gas bill fell inside the 50-85% verified saving band.

A1 / A2 vessel licensesGC1-GC3 piping designISO 9001US UL36 patents
Why references matter

Ask For The One Closest To Your Plant

Brochure numbers are easy; measured curves are not. Every project above maps to a commissioning report with capacity, purity and specific-energy test results on file. When your due-diligence team calls, we route the reference plants whose duty looks like yours - same industry, same capacity band, same climate - instead of the showcase machine.

Under NDA we go further: reference-check calls with operating owners, commissioning photo sets, and the energy datasheets owners actually run to.

Equipment loading for export shipment (scene rendering)

Get a Quote From the Factory

Your project could be the next line on this page - with your permission.